Skip to main content
  • Hoopla logo
  • Browse
  • My Hoopla
  • Log In
Books, videos, and music - all free from your public library!
LoginSign Up

Footer

Hoopla logo, Go to homepage
  • For Patrons
  • For Libraries (opens in new window)
  • For Vendors (opens in new window)
  • Facebook (opens in new window)
  • X (opens in new window)
  • Instagram (opens in new window)
  • YouTube (opens in new window)
  • TikTok (opens in new window)
  • LinkedIn (opens in new window)

Our Company

  • Our Story
  • Get Hoopla for your Library (opens in new window)
  • Get your content on hoopla (opens in new window)
  • Join our team (opens in new window)
  • Accessibility Statement

Our Content

  • Audiobooks
  • Ebooks
  • Movies
  • Television
  • Comics
  • BingePasses
  • Music
  • The Loop Blog

Help

  • Help Center
  • Submit Feedback
  • Facebook (opens in new window)
  • X (opens in new window)
  • Instagram (opens in new window)
  • YouTube (opens in new window)
  • TikTok (opens in new window)
  • LinkedIn (opens in new window)
  • Download on the App Store (opens in new window)
  • Get it on Google Play (opens in new window)
  • Available at Amazon Appstore (opens in new window)
© 2026 Midwest Tape, LLC. All rights reserved. Privacy Policy | Terms of Use
  1. Navigate Home
  2. Ebooks
  3. Introduction to Power System Protection

EBOOK

Introduction to Power System Protection

Dr. Hidaia Mahmood Alassouli
(0)
sign up
Year
2022
Language
English
Publisher
Dr. Hidaia Mahmood Alassouli

About

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria:
• Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages.
• Selectivity: Avoid unnecessary, false trips.
• Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise.
• Economy: Provide maximum protection at minimum cost.
• Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections:
1. Chapter 1: Power System Faults:
2. Chapter 2: Instrument Transformers.
3. Chapter 3: Overcurrent and Earth Fault Protection Relays.
4. Chapter 4: Radial System Protection.
5. Chapter 5: Zones of Protection.
6. Chapter 6: Differential Relays.
7. Chapter 7: Distance Relays.
8. Chapter 8: Transformer Protection.
9. Chapter 9: Generator Protection.
10. Chapter 10: Busbar Protection.
11. Chapter 11: Circuit Breakers.
12. Chapter 12: Fuses.
13. Chapter 13: References.